Start a liquid-engine project in RPL Engine Workbench 2.0.2, choose propellants and operating inputs, compare target-thrust and known-throat sizing, and save your case. Runs in the trial.
Narrated walkthrough, 1:45, recorded in RPL Engine Workbench 2.0.2. MP4, 3.3 MB.Transcript
Start from the reference project, and save a copy under your own name. The trial saves projects. In Propellants, choose liquid oxygen and R P one, at a mixture ratio of two point four. In Engine, set two megapascals in the chamber and sea-level ambient pressure. Target vacuum thrust sizes the engine around the thrust you choose: here, five thousand newtons, with an area ratio of three point four. Solve. Review shows a specific impulse of two hundred sixty-one point five seconds in vacuum, two hundred thirty-two point eight at sea level, and a forty-five point five millimetre throat. If the throat is already fixed, choose Throat diameter as the sizing basis, and enter forty-five millimetres. Solve again. Thrust now follows from the throat: four thousand eight hundred ninety-seven newtons in vacuum, at one point nine one kilograms per second. Save. The project keeps every input; reopen it and solve to get the same results.
Save a copy. Open the starting project and save it under your own name. This lesson changes it to a new LOX/RP-1 example.
Choose propellants. In Define → Propellants, choose LOX and RP-1, with mixture ratio O/F 2.4.
Set the operating inputs. In Engine, choose First-pass sizing. Use chamber pressure 2.0 MPa, ambient pressure 0.101325 MPa and expansion ratio 3.4.
Size around thrust. Choose Target vacuum thrust, enter 5,000 N and Solve. Read the Performance view in Review.
Size around a known throat. Choose Throat diameter as the sizing basis, enter 45 mm and Solve again. Read the resulting thrust and total mass flow.
Keep the case. Save your inputs; reopen and re-solve when you return to the project.
One example, two sizing choices
Calculated quantity
5,000 N vacuum target
45 mm known throat
Vacuum thrust, N
5,000
4,897
Sea-level thrust, N
4,452
4,360
Vacuum specific impulse, s
261.5
261.5
Sea-level specific impulse, s
232.8
232.8
Total mass flow, kg/s
1.950
1.910
Throat diameter, mm
45.47
45.00
Both cases use first-pass sizing, chemical-equilibrium thermochemistry and Frozen nozzle flow, with combustion efficiency 96% and nozzle efficiency 98%. These are the calculated example results shown in the video. The separate reference-check lesson compares the original operating point with published nominal data.