The app has no automatic nozzle optimizer for a fixed grain. This tutorial shows the manual sweep: change the throat diameter and the expansion ratio in Define > Motor > Nozzle and conditions, keep each solve and compare them.
Narrated walkthrough, 2:03, recorded in RPL Engine Workbench 2.1.0. MP4, 7.1 MB.Transcript
Choose File, Open Example, Solid rocket. Home draws the motor: a grain in 2 segments and a 0.3740 inch throat. There is no optimizer for the nozzle of a fixed grain. You sweep it by hand in Define, Motor, Nozzle and conditions. Click Solve motor and flight. Review gives 160.2 lbf·s total impulse and a peak chamber pressure of 512.7 psi. Click Keep this result and name it; that is your baseline. Type a smaller Throat diameter, 0.35 inch. The card says why: the throat sets chamber pressure through Kn, the ratio of burning area to throat area. Solve again. The grey line on each chart is the previous solve. Peak pressure rises to 673.3 psi, total impulse to 163.3, and the burn is shorter. No pressure warning comes up, but the Case row reads not checked: the example enters no wall. Enter your case before going smaller. Keep it. Then raise Expansion ratio from 5 to 6, solve, and keep that too. Total impulse is 164.2. Peak pressure stays at 673.3, because the throat is unchanged. On Compare, set Baseline to the example nozzle and Candidate to the smaller throat. Peak pressure is up 31.32%, total impulse 1.94%. With ratio 6 as the candidate, total impulse is up 2.50%. Inputs that differ lists the two fields you changed. Kept results shows all three. Show the warnings of the solves: the one warning on both is the flight passing Mach 0.8, not the motor. Of the three, 0.35 inch with ratio 6 gives the most impulse, on preliminary figures. The 30-day trial does every step.
A manual nozzle sweep
Open and solve the example. Choose File > Open Example > Solid rocket. Home draws the motor: a grain in 2 segments and a 0.3740 in throat. Click Solve motor and flight, then Keep this result and name it: that is your baseline.
Make the throat smaller. In Define > Motor > Nozzle and conditions, type a smaller Throat diameter, 0.35 in. The card says why it matters: the throat sets chamber pressure through Kn, the ratio of burning area to throat area.
Solve again and check the case. Solve again; the grey line on each chart is the previous solve. No pressure warning comes up, but the Case row reads not checked, because the example enters no wall. Enter your case before going smaller. Keep the result.
Raise the expansion ratio. Raise Expansion ratio from 5 to 6, solve, and keep that result too.
Compare the three. On Compare, set Baseline to the example nozzle and Candidate to the smaller throat, then to the ratio-6 result. Inputs that differ lists the fields you changed, and Kept results shows all three.
Check the warnings. Show the warnings of the solves: the one warning on both is the flight passing Mach 0.8, not the motor.
The recorded sweep
The example nozzle gives 160.2 lbf·s total impulse and a peak chamber pressure of 512.7 psi. With the 0.35 in throat, peak pressure rises to 673.3 psi and total impulse to 163.3 lbf·s, and the burn is shorter. With expansion ratio 6 as well, total impulse is 164.2 lbf·s and peak pressure stays at 673.3 psi, because the throat is unchanged. Against the example nozzle, peak pressure is up 31.32 % and total impulse 1.94 % with the smaller throat, and total impulse is up 2.50 % with ratio 6. Of the three, 0.35 in with ratio 6 gives the most impulse, on preliminary figures; the case wall was not checked.
Continue with version 2.1
Compare a design change: keep a result, change the fin span and read the differences on Compare.
Draw a custom fin outline: replace the trapezoid fin with your own outline, check the mesh and compare.